REFER TO FIG 1 & 2
The side wall clearance above the hob shall be greater than 3”.
Surfaces over the top of the range must not be closer than 28” and must not exceed 13” in depth.
The vent slots in the back of the top plate (or shroud) must not be obstructed.
Note: It is essential that the supply cable is routed away from any hot surfaces i.e. hot flue pipes.
In the interests of safety, due consideration must be given to the protection of the electric cable
to the Module/Companion.
The Module/Companion requires a 30 amp power supply and must be connected to the mains
with a cable which complies with the latest edition of the Local and National Wiring Regulations.
Remember that an excess of cable length is required for the possible withdrawal of the range.
A electrical socket type 14-30R must be provided within 5 feet of the left hand side of the range
and accessible for disconnection.
DO NOT position socket above or behind the range cooker.
An easily accessible manual shut off gas valve must be fitted before the metal flexi gas line
supply to the range. DO NOT fit valve behind the range cooker.
Any opening in the wall behind the appliance and in the floor under the appliance must be
sealed.
LEVELLING
The Aga Companion is designed to stand on a flat surface, however any unevenness may be
overcome by packing under the corners of the plinth with a suitable non-combustible material,
(up to 1/8”).
COMPANION ONLY
Ranges must have an anti-tip device correctly installed as per these instructions. If you pull the
range out from the wall for any reason, make sure that the device is properly engaged when you
push the range back against the wall. If it is not, there is a possible risk of the range tipping over
and causing injury if you or a child stand, sit or lean on an open door.
To reduce the risk of tipping, the range must be secured by a properly installed anti-tip bracket
supplied with the range. The bracket must be fitted within the shaded area shown in the diagram
using 2 x screws (No.10 x 1 1/4”) fixed in the wall or floor, longer screws may be required
depending on the wall or floor covering.