Divator MKII Face maskInstruction manual
11REMOVING THE MASK1. Unlock the buckles and loosen thehead harness.2. Turn off the positive pressure bypressing the black lever on thebreathing valve
12CLEANINGDaily care:1. Immerse the face mask and the breathing valve into clean water.2. Remove the mask and the breathing valve from the water.3. Pr
135. Dismantle the breathing valve inthe following way:a) Unscrew the locking ring and re-move the positive pressure unitfrom the valve housing.b) Sea
14e) Remove the positive pressurespring and the guide disc from thepositive pressure unit cover.d) Remove the sealing disc and theexhalation diaphragm
156. Wash the face mask and the breathing valve dismantled as described above.Use soap and warm water (maximum 40 °C). Scrub with a brush if necessary
16ASSEMBLY AFTER CLEANING1. Check that the rubber parts are supple and without cracks or other defects.Damaged parts should immediately be replaced. A
17FUNCTION TEST AFTER CLEANING1. Connect the breathing hose to the breathing valve and push the lever to theoff position (i.e. against the valvehousin
18Diving in low water and/or airtemperaturesColder environments always involve greater risk of freezing in a breathing ap-paratus. We recommend the us
192. Face maskThe face mask has been developed in order to protect the diver's face againstcold and to make it possible to warm and moisten the b
20
ContentsSpecial points 5Technical description 6Face mask 6Low volume diving visor 6Breathing valve 7Breathing valve with positive pressure 7Usage 8Pre
21
AMERICAS: Interspiro Inc., 31 Business ParkDrive, BRANFORD, CT06405.Phone+12034813899, Telefax +120348318 79AUSTRIA: Interspiro GesmbH, Fritz-Knoll-St
4
5Special pointsThe full-face masks are intended only for the use stated in this usermanual. Exceptions can be agreed only in writing.Servicing, cleani
6If it is required to trim the mask to a neutral buoyancy,weights are available which can be attached to locating lugs(art. no. 336 190 854) on each s
7BREATHING VALVEThe breathing valve is of the demand type i.e. air is only supplied during inhala-tion.Owing to the balanced valve function the breath
8UsagePREPARATION1. Connect the breathing valve to themask by pushing the valve into theconnection piece and by turning itanti clock-wise so that it g
9DONNING1. Adjust the pressure equalizer padto a position which permits easybreathing through the nose.2. Pull out the head harness straps asfar as po
104. If necessary, pressure equalize bypressing the breathing valve up-wards.4. Check the positive pressure byholding the breath and insertingtwo fing