AGA LITTLE WENLOCK Wartungshandbuch

Stöbern Sie online oder laden Sie Wartungshandbuch nach Kamine AGA LITTLE WENLOCK herunter. AGA LITTLE WENLOCK Technical data Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 16
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
LITTLE WENLOCK
GAS STOVE
INSTALLATION AND OPERATION INSTRUCTIONS
To ensure safety, satisfaction and reliable service this stove should be installed by a suitably qualified
and competent person.
This appliance is hot while in operation and retains its heat for a long period of time after use. Children,
aged or infirm persons should be supervised at all times and should not be allowed to touch the hot work-
ing surfaces while in use or until the appliance has thoroughly cooled.
Seitenansicht 0
1 2 3 4 5 6 ... 15 16

Inhaltsverzeichnis

Seite 1 - GAS STOVE

LITTLE WENLOCK GAS STOVEINSTALLATION AND OPERATION INSTRUCTIONSTo ensure safety, satisfaction and reliable service this stove should be installed by

Seite 2 - PAGE NO

FACTORY-MADE INSULATED CHIMNEY’SFactory-made insulated chimneys must be con-structed and tested to meet the relevant standardsand recommendations give

Seite 3 - OPERATION INSTRUCTIONS

WARNING: To avoid pipe sealing compoundsfrom entering into the gas train, do not apply seal-ing compound to the first two threads at the tip ofthe gas

Seite 4 - Low Flame Setting

4. Place 4 medium coals on the front of the matrix with their corners touching and also one corner of each coal resting on a spar. (see Fig.26)Fig.26

Seite 5

WARNING: Do not operate the stove with theappliance door open, or if the glass panel in thefront door has been broken or removed.Ensure the door latc

Seite 6

Fig.33Fig.34Fig.35Fig.36Fig.37ENAMEL CLEANINGGeneral cleaning must be carried out when thestove is cool.If this stove is finished in a high gloss vitr

Seite 7

14LITTLE WENLOCK GAS EXPLODED VIEW1. Leg2. Front Frame3. Blanking Plate4. Flue Spigot5. Hob6. LH & RH Side Panels7. Back Casting8. Base9. Burner N

Seite 8

TROUBLE SHOOTING GUIDEPROBLEM POSSIBLE CAUSE SOLUTIONPilot will not light No gas Check gas is turned on.Safety interlock preventing Wait 5 minutes &a

Seite 9

TABLE OF CONTENTSPAGE NO.1. Operation Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 10

OPERATION INSTRUCTIONSWARNING: Do not operate the stove with theappliance door open, or if the glass panel in thefront door has been broken or removed

Seite 11

Fig.47. To turn off the main burner, turn the control knob in a clockwise direction to low flame. (see Fig. 4)Fig. 58. While pressing the control knob

Seite 12

TECHNICAL DATAPressure Setting From ColdNatural Gas Inlet Pressure = 8”/20mbarProduct Identification No.: 0063 AS 5164Appliance Category BIIBSCountry

Seite 13 - INCORRECT FLAME

This appliance has been tested and approvedin accordance with the essential requirementsof Annex 1 in the Gas Appliance Directive(90/396/EEC) as amend

Seite 14 - /4” slotted head screw from

Fig.11Fig.12When installing the stove against acombustible wall leave a 6” spacebetween the back of the stove andthe wall for air circulation.(See Fig

Seite 15

CHIMNEY’S / FLUESIf connecting to a rear exit configuration the hori-zontal run should not exceed 300mm (12”) fromthe stove outlet. (see fig.17)The he

Seite 16 - TROUBLE SHOOTING GUIDE

Fig.18Fig.198USE OF EXISTING CHIMNEYS AND FLUES(See Figs. 18, 19 & 20)An existing flue pipe or chimney that has proved tobe satisfactory when used